NOTI-FIRE-NET
- High-Speed NOTI•FIRE•NET (HS-NFN) is the interface which allows NOTIFIER Intelligent Fire Alarm Control Panels to form a network. Each local control panel (network node) maintains its own area of protection, while monitoring and controlling other areas (other network nodes). Allows for up to 200 node addresses.
- Local information is displayed at each network node. In areas such as a security office, where the entire network must be monitored, network annunciators are available.
NOTE: High-Speed Noti•Fire•Net is NOT compatible with Noti•Fire•Net.
• Multi-mode fiber optic (MF), single-mode fiber optic (SF), wire (W), or a combination of W/MF/SF communications path.
• NFPA Style 4 or Style 7 network operation.
• True peer-to-peer communications. Each node stores its own program and communicates equally with all other nodes.
• No “master” polling computer or other central weak link.
• Inherently regenerative system. Each node acts as a repeater to reshape and regenerate data signals. Failure of any node does not affect any other node/communications among surviving nodes.
• High-speed data communications (12 Mb wire, 100 Mb MF/ SF fiber) operates several times as fast as competitive networks.
• Simple plug-in module. The HS-NCM connects the NFS2- 3030, NFS-3030, NFS2-640, NFS-640, NFS-320, NCA-2, NCA, DVC, ONYXWorks, BACnet Gateway, and NWS/ NWS-3.
• Multiple ONYXWorks® may be placed anywhere on the network. Additional ONYXWorks may be used to provide inherent “hot” backup.
• Multiple Network Control Annunciators (NCA/NCA-2) may be placed anywhere on the network.
• ONYXWorks, NCA and NCA-2 display all network activity. Unlike competitive systems, the point display capacity is NOT held to less than the maximum network capacity.
• Single small-gauge (18 AWG to 14 AWG) twisted-pair wire (no shield necessary) for data communications path.
• Electrical isolation between nodes.
• Network clock synchronization (see page 3).
• History Buffers on NCA-2, NCA, ONYXWorks, NFS2-3030, NFS-3030, NFS2-640, NFS-640, and NFS-320 Intelligent Fire Control Panels.
• Powerful Cooperative-Control-by-Event allows point(s) on one node to activate point(s) on other nodes. Any input can turn on any output, network-wide.
• ONYXWorks Workstation See ONYXWorks data sheet, DN-7048.
• NCA Network Control Annunciator See NCA data sheet, DN-6858.
• NCA-2 ONYX Network Control Annunciator See NCA-2 data sheet, DN-7047
• HS-NCM-W/MF/SF/WMF/WSF/MFSF Network Communications Module See High-Speed Network Communications Modules data sheet, DN-60454. Compatible panels: NFS-320, NFS-640, NFS2-640, NFS-3030. NFS2-3030.
• BACnet Gateway See BACNET-GW-3 data sheet, DN-6877.
• NWS-3 NOTI•FIRE•NET™ Web Server See NWS-3 data sheet, DN-6928.
• NFN-GW-EM-3, DN-7060
• DVC, DN-7045
• Modbus Gateway See MODBUS-GW datasheet, DN-60533
- UL/ULC Listed: S635 (HS-NCM, Printer), S5526 (ONYXWorks)
- FM Approved (HS-NCM)
- CSFM: 7300-0028:0257 (HS-NCM), 7300-1525:0103:0103(ONYXWorks)
- FDNY: COA #6022 (HS-NCM), COA #6041 (ONYXWorks)