NFS-320 Intelligent Addressable Fire Alarm System (3 loop)

  • General Description

    • The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement.
    • The NFS-320’s modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. Wireless fire protection can be added with the SWIFT wireless gateway and devices. For installations using NFS-320C, an optional ACM Series annunciatorcan be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). NOTE: Unless called out with a version-specific “R”, “C” or “E” at the end of the part number, “NFS-320” refers to models NFS-320,NFS-320R, NFS-320C, and NFS-320E.

    本頁圖片/檔案 - notifier-nfs2-320

     

  • Features

    • Certified for seismic applications when used with the appropriate seismic mounting kit.
    • Approved for Marine applications when used with listed compatible equipment. See DN-60688.
    • One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7.
    • Up to 159 detectors and 159 modules per SLC; 318 devices maximum.
    – Detectors can be any mix of ion, photo, thermal, or multi-sensor; wireless detectors are available for use with the FWSG.
    – Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG.
    • Optional FWSG Wireless SWIFT Gateway supports wireless SLC devices.
    • Standard 80-character display.
    • Network options:
    – High-speed network for up to 200 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA).
    – Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVCEMis used in network paging.
    • 6.0 A power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization.
    • Built-in Alarm, Trouble, Security, and Supervisory relays.
    • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware.
    • Autoprogramming and Walk Test reports.
    • Multiple central station communication options:
    – Standard UDACT
    – Internet
    – Internet/GSM
    • 80-character remote annunciators (up to 32).
    • EIA-485 annunciators, including custom graphics.
    • Printer interface (80-column and 40-column printers).
    • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file.

    Alarm Verification selection per point, with automatic counter.
    • Presignal/Positive Alarm Sequence (PAS).
    • Silence inhibit and Auto Silence timer options.
    • NAC coding functions:
    – March time.
    – Temporal.
    – California two-stage coding.
    – Canadian two-stage.
    – Strobe synchronization.
    • Field-programmable on panel or on PC with VeriFire® Tools program check, compare, simulate.
    • Full QWERTY keypad.
    • Battery charger supports 18 – 200 AH batteries.
    • Non-alarm points for lower priority functions.
    • Remote ACK/Signal Silence/System Reset/Drill via monitor modules.
    • Automatic time control functions, with holiday exceptions.
    • Extensive, built-in transient protection.
    • Powerful Boolean logic equations.

     

  • Data Sheet

    Download

    NFS-320 intelligent addressable fire alarm system

  • Specification

     Primary input power
    – NFS-320: 120 VAC, 50/60 Hz, 5.0 A.
    – NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A.
    Current draw (standby/alarm):
    – NFS-320(E) board: 0.250 A. Add 0.035 A for each NAC in use.
    – KDM-R2 (Backlight on): 0.100 A.
    • Total output 24 V power: 6.0 A in alarm.
    NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet.
    • Standard notification circuits (4): 1.5 A each.
    • Resettable regulated 24V power: 1.25 A.
    • Two non-resettable regulated 24V power outputs:
    – 1.25 A.
    – 0.50 A.
    • Non-resettable 5V power: 0.15 A.
    • Battery charger range: 18 AH – 200 AH. Use separate cabinetfor batteries over 26 AH.
    • Float rate: 27.6 V.

     

  • Certification

    • UL 864 (Fire).
    •  UL 1076 (Burglary).
    •  UL 2572 (Mass Notification Systems). (NFS-320 version 20 or higher).
    • ULC-S527-11 Standard for the Installation of Fire Alarm System
    • LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory).
    •  AUXILIARY (Automatic, Manual and Waterflow) (requires TM- 4).
    •  REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4).
    •  PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM.
    •  CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires DACT).
    • EMERGENCY VOICE/ALARM.
    • OT, PSDN (Other Technologies, Packet-switched Data Network).
    • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic).
    • CBC 2007 (Seismic).

     

     

     

     