- MAYSUN ENGINEERING COMPANY LIMITED - https://maysun.com.hk -

RP-2002

  • General Description

    • The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The RP-2002 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

  • Features

    • Listed to UL Standard 864, 9th edition.
    • FM Approved.
    • Designed for agent releasing standards NFPA 12, 12A,12B, and 2001.
    • Meets International Building Code (IBC) seismic requirements.
    • Disable/Enable control per input zone and output zone.
    • Extensive transient protection.
    • Dual hazard operation.
    • Adjustable pre-discharge, discharge and waterflow delay timers.
    • Cross-zone (double-interlock) capability.
    • Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
    • System Sensor i3 series detector compatible.
    • Four programmable Style Y (Class B) output circuits - (special application power).
    Strobe synchronization:
    – System Sensor

    – Wheelock

    – Gentex
    – Faraday
    – Amseco
    • Three programmable Form-C relays.
    • 7.0 amps total 24 VDC output current.
    • Resettable and non-resettable output power.
    • Built-in Programmer.
    ANN-BUS connector for communication with optional devices (up to 8 total of any of the following)
    – N-ANN-80 Remote LCD Annunciator
    – N-ANN-I/O LED Driver
    – N-ANN-S/PG Printer Modules
    – N-ANN-RLY Relay Module
    – N-ANN-LED Annunciator Module
    • 80-character LCD display (backlit).
    • Real-time clock/calendar with daylight savings time control.
    • History log with 256 event storage.
    • Piezo sounder for alarm, trouble and supervisory.
    • 24 volt operation.
    • Low AC voltage sense.
    Outputs Programmable for
    – Releasing Circuits or NACS
    NACs programmable for
    – Silence Inhibit
    – Auto-Silence
    – Strobe Synchronization
    – Selective Silence (horn-strobe mute)
    – Temporal or Steady Signal
    – Silenceable or Non-silenceable

    – Release Stage Sounder

    • Automatic battery charger with charger supervision.
    • Optional Dress Panel DP-51050 (red).
    • Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
    • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
    • Optional 4XTM Municipal Box Transmitter Module.
    • Optional Digital Alarm Communicators (411, 411UD, 411UDAC).
    • Optional ANN-SEC card for a secondary ANN-BUS.

     

  • Data Sheet

    Download

    RP-2002 Agent Release Control Panel

     

     

  • Specification

    • RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps
    • RP-2002E (FLPS-7 Power Supply): 240 VAC, 50/60 Hz, 2.085 amps
    • Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, nonpower-limited Cabinet Specifications

     

  • Certification

    • UL: S635
    • FM approved
    • CSFM: 7165-0028:0245
    • MEA: 333-07-E
    • Seismic Listing: Reference certificiate of compliance VMA - 45894-01 by the VMC Group

     