  • General Description

    • The RP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The RP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The RP-2001 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

  • Features

    • Listed to UL Standard 864, 9th edition.
    • FM Approved.
    • Designed for sprinkler standards NFPA 13, 15 and 16.
    • Dual hazard operation.
    • Adjustable waterflow discharge timer and two soak timers.
    • Cross-zone (double-interlock) capability.
    • Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
    • System Sensor i3 series detectors compatible.
    • Four programmable Style Y (Class B) output circuits - (special application power).
    • Strobe Synchronization:
    – System Sensor
    – Wheelock
    – Gentex
    – Faraday
    – Amseco
    • Three programmable Form-C relays.
    • 7.0 amps total 24 VDC output current.
    • Resettable and non-resettable output power.Built-in Programmer.
    • ANN-BUS for connection to optional devices (up to 8 total of any of the following):
    – N-ANN-80 Remote LCD Annunciator
    – N-ANN-I/O LED Driver
    – N-ANN-S/PG Printer Module
    – N-ANN-RLY Relay Module
    – N-ANN-LED Annunciator Module
    • 80-character LCD display (backlit).
    • Real-time clock/calendar with daylight savings time control.
    • History log with 256 event storage.
    • Piezo sounder for alarm, trouble and supervisory.
    • 24 volt DC operation.
    • Low AC voltage sense.
    • Outputs Programmable for:
    – Releasing circuits or NACS
    • NACs programmable for:
    – Silence Inhibit
    – Auto-Silence
    – Strobe Synchronization
    – Selective Silence (horn-strobe mute)
    – Temporal or Steady Signal
    – Silenceable or Non-silenceable
    – Release Stage Sounder
    • Disable/Enable control per input zone and output zone.
    • Extensive transient protection.
    • Automatic battery charger with charger supervision.
    • Optional Dress Panel DP-51050 (red).
    • Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
    • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
    • Optional 4XTM Municipal Box Transmitter Module.

    • Optional Digital Alarm Communicators (411, 411UD, 411UDAC).
    • Optional ANN-SEC card for a secondary ANN-BUS.

     

  • Data Sheet

    Download

    RP-2001 Preaction Control Panel

     

     

  • Specification

    • RP-2001 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps.
    • RP-2001E (FLPS-7 Power Supply): 240 VAC, 50/60 Hz, 2.085 amps.
    • Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, nonpower-limited.

     

  • Certification

    • UL: S635
    • FM approved
    • CSFM: 7165-0028:0245
    • MEA: 333-07-E