FLM‑420‑NAC Signaling Device Interface Modules
- General Description
- FLM‑420‑NAC Signaling Device Interface Modules make it possible to monitor and activate a group of signaling devices (NAC = Notification Appliance Circuit) in the Local SecurityNetwork LSN. Each interface module offers one monitored primary line. This means one signaling device line can be connected to LSN fire panels.
- Features
- Rotary switches for automatic or manual address setting
- Control of signaling device line by pole reversal
- Synchronized activation of all signaling devices connected to a LSN module via FLM‑420‑NAC Signaling Device Interface Module
- Ten different output signals via LSN selectable
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
- Available with surface-mounted housing or DIN rail adapter
- Data Sheet
Download
FLM‑420‑NAC Signaling Device Interface Modules
- Specification
Input voltage 15 V DC to 33 V DC Max. current consumption from LSN 6,06 mA (normal operation and alarm) from external power supply 15 mA (normal operation) + output current External power supply 20,4 V DC to 29 V DC Max. output current 3 A (during an alarm, from ext. power supply) EOL resistance 3.9 kΩ Display elements Red LED Alarm Green LED Normal operation LSN/Address setting 3 rotary switches for Mode LSN "classic" or LSN improved version Automatic or manual addressing Connections 12 threaded clamps Max. wire diameter for terminals 3.3 mm2 (12 AWG) Housing material Interface module PPO (Noryl) Surface-mount housing ABS/PC-Blend Housing color Interface module Off-white, similar to RAL 9002 Surface-mount housing Signal white, RAL 9003 Dimensions FLM-420-NAC-S Approx. 126 x 126 x 71 mm(4.96 x 4.96 x 2.8 in.) FLM-420-NAC-D (with DIN rail adapter) Approx. 110 x 110 x 48 mm(4.33 x 4.33 x 1.89 in.) Weight FLM-420-NAC-S Approx. 390 g (13.8 ounces) FLM-420-NAC-D (with DIN rail adapter) Approx. 150 g (5.3 ounces) Number of zones per signaling device interface module 1 Output signals Steady BS 5839 March Time March Time 120 California Coded Synchronization protocol (Wheelock, Gentex) Permitted operating temperature -20 °C to 50 °C(-4 °F to 122 °F) Permitted storage temperature -25 °C to 80 °C(-13 °F to 176 °F) Permitted relative humidity < 96% Classes of equipment as per IEC 60950 Class III equipment Protection class as per IEC 60529 FLM-420-NAC-S IP 54 FLM-420-NAC-D IP 30 - Certification